A UPFLOW FURNACE
WARNING: A SOLID METAL BASE
PLATE (see table below or furnace
clearance label for part number)
MUST BE IN PLACE IF INSTALLING
THE FURNACE WITH SIDE OR
REAR AIR RETURN. FAILURE TO
INSTALL A BASE PLATE COULD
CAUSE PRODUCTS OF COMBUS-
TION TO CIRCULATE INTO THE
LIVING SPACE AND CREATE
POTENTIALLY HAZARDOUS
CONDITIONS, INCLUDING
CARBON MONOXIDE POISONING.
The furnace comes with the optional
base plate installed when ordered
under the new option code #263.
A WARNING: DO NOT PLACE
COMBUSTIBLE MATERIAL ON OR
AGAINST THE FURNACE JACKET
OR WITHIN THE SPECIFIED
CLEARANCES OF THE VENT PIPE.
KEEP THE AREA AROUND THE
FURNACE CLEAR AND FREE OF
ALL COMBUSTIBLE MATERIALS
INCLUDING GASOLINE AND
OTHER FLAMMABLE VAPORS AND
LIQUIDS. A FLAME FROM THE
TABLE 15
BASE PLATE INSTALLATION
FURNACE SOLID BOTTOM
BASE
WIDTH KIT NO.
PLATESIZE
14" RXGB-D14 115/a"X 239/16'
17½'
RXGB-D17 15
1
/a"
X 23
9
/16"
21"
RXGB-D21
185/a' X 239/16'
24½"
RXGB-D24 25
5
/a' X 239/15'
FURNACE MAY IGNITE FLAM-
MABLE VAPORS RESULTING IN
FIRE, EXPLOSION, PERSONAL
INJURY, OR DEATH. CAUTION THE
FURNACE OWNER THAT THE
FURNACE AREA MUST NOT BE
USED FOR ANY OTHER STORAGE
PURPOSES.
A CAUTION: IF USING AN AIR
CONDITIONING EVAPORATOR
COIL WITH THE FURNACE AND
INSTALLING ABOVE A FINISHED
CEILING OR LIVING AREA, PLACE
AN AUXILIARY SHEET METAL
CONDENSATE DRAIN PAN UNDER
THE ENTIRE UNIT. FAILURE TO
PROVIDE SUCH A DRAIN PAN MAY
RESULT IN WATER OVERFLOW
CAUSING PROPERTY DAMAGE.
FIGURE 19
BASE PLATE INSTALLATION