Page 65
Partition “A” Secondary Output Options
P411E-P418E OPTIONS
P521E Area "A" secondary options for output #1 - Default 0 1 = Any bypass Page 24
P522E Area "A" secondary options for output #2 - Default 0 2 = Auto bypass warning Page 24
P523E Area "A" secondary options for output #3 - Default 0 3 = Entry beeps Page 24
P524E Area "A" secondary options for output #4 - Default 0 4 = Exit beeps Page 24
P525E Area "A" secondary options for output #5 - Default 0 5 = Follow Set Arming Page 24
P526E Area "A" secondary options for output #6 - Default 0 6 = Follow Stay Arming Page 24
P527E Area "A" secondary options for output #7 - Default 0 7 = Follow Unset Page 24
P528E Area "A" secondary options for output #8 - Default 0 8 = Spare Page 24
Programming Partition “A” Auto Arm/Disarm Time-zones
P529E Time Zones used for Area "A" auto arming /disarming- Default 0 (see P532E) Page 25
Partition “A” Misc Options
P530E Misc partition options 1 - Default = 6 1 = Cannot Arm if not sealed Page 25
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required to “Bypass” zones
6 = Control/Chime disables day zones
7 = Repeat System PA messages
8 = Spare
P531E Misc partition options 2 - Default 3,4,6 1 = Key-switch enabled Page 26
2 = Use 2nd Key-switch
3 = Key-switch ARM's/STAY
4 = Pendant chirps when Armed
5 = Pendant chirps when in Stay Mode
6 = 2 sec pulse at set
7 = 2 sec pulse at unset
8 = Spare
P532E PARTITION "A" TIME AND DELAY OPTIONS-Default = 0 Page 27
1 = Set partition When Time Zone Ends
2 = Unset Partition When Time Zone Starts
3 = Disable Stay Mode Exit Delay
4 = Disable Set Mode Exit Delay
5 = Disable Stay Mode Entry Delay
6 = Disable Set Mode Entry Delay
7 = Use special Stay Mode entry timer
8 = Report Stay Mode alarms & Bypasses via dialler
Enabling Local PA Message Options
P533E 1 = Enable PA Disarm msg -Default = 0 Page 27
2 = Use Canned PA Disarm msg
3 = Repeat PA Disarm msg
4 = Spare
5 = Enable PA Armed msg
6 = Use Canned PA Armed msg
7 = Repeat PA Armed msg
8 = Spare
P534E 1 = Enable PA Stay Armed msg -Default = 0 Page 28
2 = Use Canned PA Stay Armed msg
3 = Repeat Stay PA Armed msg
4 = Spare
5 = Spare
6 = Spare
7 = Spare
8 = Spare
** Dialler Reporting Options for partition “A” **
P535E Area A reporting options -Default = 1,2 Page 29
1 = Send arm / disarm 5 = Send arm when exit delay expires (LED On)