22.3 Allocating key function
It is possible to allocate the softkeys in Meas Mode Screens to suit the measurement
conditions. The current softkey allocations are retained until they are revised again,
even when the power is cut off. It is possible to register three sets of key function
allocations: Def.1, Def.2 and Def.3 and these allocations can be recalled at anytime.
Improvements in productivity may be realized by setting key functions so that
instrument functions might match specific job requirements.
In the Status Mode screen, pressCNFGto go to the config mode. Select 3. Key
function and press to go to the key function menu. In this menu, the following
operations can be done.
l Allocating softkeys
l Registering a softkeys allocation
l Recalling a softkeys allocation
When softkey allocations are recorded and registered, the previously recorded key
settings are cleared. When a softkey array is recalled, the key array is changed to the
key array that has been recalled, clearing the previous key array.
22.3.1 Defining softkeys
The following are the softkey allocations in Meas mode when the instrument was
shipped: (DEFAULT USED IN THIS MANUAL)
Page 1 DIST SHV HSET EDM
Page 2 0SET CRD S-O REC
Page 3 MLM RESE MENU HT
The following functions can be allocated to the softkeys.
DIST】: Distance measurement
SHV】: Switch between angle display and distance display
HSET】: Set required horizontal angle
EDM】: Setting EDM
0SET】: Set horizontal angle to 0
CRD】: Coordinates measurement
S-O】: Setting-out measurement
REC】: To record mode
MLM】: Missing line measurement
RESE】: Resection measurement