Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual, os 30
97
24 NOVEMBER 2015
Keep adjusting the Field Weakening Drive value and repeating the test
until you nd the Field Weakening Drive value that results in the smallest
Time Between Speeds. is Field Weakening Drive value should be used
for applications that require the most torque at high speeds.
Some Field Weakening Drive settings may result in a test acceleration
run where Capture Speed 2 cannot be obtained. ese Field Weakening
Drive settings cannot provide enough torque to get the vehicle past Cap-
ture Speed 2. e nal setting used for Field Weakening Drive should be
somewhere between 0% (most ecient, least motor heating) and the setting
found in this test (highest torque at high speeds).
Note: e Field Weakening Drive setting will have no eect at motor speeds
below FW Base Speed.
17. Return to Section 5 and complete Initial Setup steps