2.60. TIMESYNC
These log messages refer to the TIMESYNC (Firewall time synchronization events) category.
2.60.1. synced_clock (ID: 03500001)
Default Severity NOTICE
Log Message The clock at <oldtime>, was off by <clockdrift> second(s) and
synchronized with <timeserver> to <newtime>
Explanation The clock has been synchronized with the time server.
Gateway Action None
Recommended Action None.
Revision 2
Parameters oldtime
newtime
clockdrift
timeserver
2.60.2. failure_communicate_with_timeservers (ID: 03500002)
Default Severity WARNING
Log Message Communication with the timeserver(s) failed. Clock not updated.
Explanation The unit failed to establish a connection with the time sync server.
The clock has not been updated.
Gateway Action clock_not_synced
Recommended Action Verify that the time sync server is running.
Revision 1
2.60.3. clockdrift_too_high (ID: 03500003)
Default Severity WARNING
Log Message According to the timeserver the clock has drifted <clockdrift>
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
Explanation The clock has drifted so much that it is not within the allowed +/-
correction interval. The clock will not be updated.
Gateway Action clock_not_synced
Recommended Action If the correction interval is too narrow, it can be changed in the
Advanced Settings section.