xStack
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch
141
Loopdetect Trap
None – The trap will not be sent in any situation.
Loop Detected – The trap is sent when the loop condition is detected.
Loop Cleared – The trap is sent when the loop condition is cleared.
Both – The trap will be sent for both conditions.
Interval (1-32767)
Enter a time interval, between 1 and 32767 seconds, that CTP packets will be dispatched from
loop-back detection-enabled ports. The default setting is 10 seconds.
Recover Timer (0 or
60-1000000)
Enter a time, in seconds that a port will have to wait before being recovered from a loop-back
detection shutdown. The user may set a time between 60 and 1000000 seconds with a default
setting of 60 seconds. The user may also enter a time of 0, which means that the port can only
be recovered manually by the user. This is done by going to the Port Settings window
(Administration > Port Configuration) and manually enabling these ports.
Mode
Use the pull-down menu to select Port Based or VLAN Based.
From… To
Choose a port or group of ports that are to be enabled for the loop-back detection function.
State
Use the pull-down menu to enable or disable the loop-back function for the selected ports.
Click Apply to implement changes made.