3.5 Writing the setup data
3-16
3.5 Writing the setup data
This section describes the procedure for writing the setup data you created in "3.4 Creating the setup data" onto
Welding Interface (Digital) and the robot controller.
3.5.1 Writing the setup data onto the robot controller
Write the setup data you created in "3.4.2 Configuring the welding mode for the Welbee Inverter
series welding power source" onto the robot controller.
Writing the setup data onto the robot controller
While the power of the robot controller is OFF, insert the backup CF card that
you created in "3.4.2 Configuring
the welding mode for the Welbee Inverter
series welding power source" into the robot controller.
While the power of the robot controller is ON,
Select “1 File Copy” on the file operation menu, and press [Enter].
>> The [File Copy] screen is now opened.
Select "Card 1" in the Device (src) selection field.
To move through each field, use the [left or right] keys.
To select the items displayed in the fields, use the [up or down] keys.
In "Card 1", select the folder that stores the backup, select "WORK" →
"A_APPLICATION" → "WELD" in this order, and then press [Enter].
>> The "WELD" folder is selected.