Parameter
Selection
Unit
Description
SS2 td1
20...65535
ms
Use this parameter to set the time after the activation of the function during
which the ramp monitoring must start (when ramp monitoring is used).
SS2 td2
0...65535
ms
Use this parameter to set the time delay for the activation of the SOS func-
tion after speed goes below zero speed (when zero speed monitoring is
used).
SOS Revolu-
tion Limit
0.01...100.00
revolu-
tions
Use this parameter to set the allowed deviation from the initial position after
the SOS function has started.
8.7 SQS Parameters
Table 74: SQS Parameters
Parameter
Selection
Unit
Description
Acknowledgment
Mode (SQS)
Manual
Automatic
Use this parameter to select if manual (external) acknowledgment is necessary to deac-
tivate the safety function after the request ends. If the selection is automatic, the func-
tion is deactivated after the request ends.
SQS Type
STO
SS1
SS2
Use this parameter to set the behavior of the SQS function.
Table 75: The Parameters for SQS-SS1 and SQS-SS2
Parameter
Selection
Unit
Description
SQS Monitor-
ing
Time.
Time + Zero
Speed.
Time + Zero
Speed + Ramp.
Use this parameter to select if zero speed monitoring and ramp monitoring are
used for the SQS-SS1 or the SQS-SS2 function.
SQS t1
0...3 000 000
ms
Use this parameter to set the time after which the STO or the SOS function activates
(when only time monitoring is used), or after which the SQS function must be
reached (when zero speed monitoring is used).
SQS td1
20...65535
ms
Use this parameter to set the time after the activation of the function during which
the ramp monitoring must start (when ramp monitoring is used).
SQS td2
0...65535
ms
Use this parameter to set the time delay for the activation of the STO+SBC or the
SOS function after speed goes below zero speed (when zero speed monitoring is
used).
SQS Ramp
Speed
0...65535
rpm
Use this parameter to set the nominal speed used to define the SQS ramp.
SQS Ramp Dec
Time Min
0...3 000 000
ms
Use this parameter to set the minimum time for the speed to decelerate from SQS
Ramp Speed to zero.
SQS Ramp Dec
Time Max
0...3 000 000
ms
Use this parameter to set the maximum time for the speed to decelerate from SQS
Ramp Speed to zero.
AQ319736045637en-000101 / DPD01798 | 131Danfoss A/S © 2021.06
Parameter List
VACON® NXP Advanced Safety Options
Operating Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON OPTEA and is the answer not in the manual?

Danfoss VACON OPTEA Specifications

General IconGeneral
BrandDanfoss
ModelVACON OPTEA
CategoryDC Drives
LanguageEnglish

Related product manuals