Technical item or function
Minimum
Typical
Maximum
Operating Frequency
–
–
350 kHz
Pulse length for signal Z
1/4*T ≈ 0.7 us
–
–
Termination resistor
200 Ω if used, cannot be used with HTL encoder.
Cable length
See recommendation of encoder manufacturer.
Conductor size/cross-section (AWG)
0.14 mm
2
(26)
–
0.5 mm
2
(20)
1
Single-ended encoders or single-ended encoder connections are not supported.
Proximity sensors connected to Digital input 1 and 2 of the safe I/O. Also see technical data for inputs.
Table 95: Proximity Sensors
Technical item or function
Minimum
Typical
Maximum
Supported types
4-wire PNP
Duty cycle (Signal ACTIVE-INAC- TIVE ratio)
1%
50% (1:1 ratio)
99%
Operating Frequency
–
–
10 kHz (50% dutycycle) 0.2 kHz
(1% or 99% duty cycle)
Pulse length
50 µs
–
–
Recommended value for the safety function speed limit (see
3.6.5 Proximity sensors)
15000/ppr
–
–
Table 96: Estimated Speed
Technical item or
function
Minimum
Typical
Maximum
Supported motor
types
Asynchronous motor (ASM), also known as induction motor (IM). Synchronous motor (SM), which typically
is permanent magnet synchronous motor (PMSM).
Supported speed
range
0 Hz
–
Approximately 200% of the motor nominal
speed, or 320 Hz.
Estimation error
–
ASM: < 50% of nominal slip.
(1)
SM: Esti-
mated speed = actual speed.
ASM: Approximately ± 50% of nominal slip.
(1)
Speed estimation
active
Speed estimation is active only when the AC drive is in RUN state.
1
With an asynchronous motor, the estimation is typically less reliable at low speeds and more reliable at high speeds.
The effects of external accelerative forces are not taken into account in the values above. The values are valid in these conditions:
The motor parameters have been set correctly, and the motor identification run has been completed successfully.
The motor is not overloaded.
AQ319736045637en-000101 / DPD01798148 | Danfoss A/S © 2021.06
Technical Data
VACON® NXP Advanced Safety Options
Operating Guide