Abbreviation
Definition
Parameter file
A configuration file that contains the parameters for an Advanced safety option board.
Unverified parame-
ter file
A parameter file that contains parameters that have not been verified by an Advanced safety option
board.
Verified parameter
file
A parameter file that contains parameters that have been verified and can be used in an Advanced safety
option board.
Validated parameter
file
A verified parameter file that contains parameters that have been tested and approved in the system.
PFH
Probability of failure per hour. Valid for systems that operate in a high demand mode or continuous
mode.
PFH
d
Probability of dangerous failure per hour.
PFD
Probability of failure on demand. The probability that the safety function does not work when requested.
Valid for systems that operate in a low demand mode.
PL
Performance Level
PLC
Programmable Logic Controller
PMSM
A permanent magnet synchronous motor
PROFIBUS
Standardized fieldbus protocol for RS-485 communication.
PROFIdrive
A specification for implementing AC drive related behavior over PROFIBUS/ PROFINET.
PROFINET
Standardized fieldbus protocol for Ethernet communication.
PROFIsafe
A safe fieldbus layer that operates over PROFIBUS/PROFINET.
Reached
A safety function that is reached has stopped the drive (safe stopping functions), or reached a safe area
for the measured value and monitoring for leaving the area has been activated (safe monitoring func-
tions).
Resettable fault
An error in that can be reset with a reset signal.
Reset (signal)
A signal used to reset the current violations and faults in the drive and/or the Advanced safety option
board and to deactivate the STO function after a violation or fault.
SFF
Safe Failure Fraction
Safe monitoring
function
A safety function that monitors a specific value, usually speed.
Safe stopping func-
tion
A safety function intended to stop the motor.
Safe range
A range where the monitored value can be. Exceeding the limits of a safe range will cause a violation of
the safety function.
Safe state
A state of a device or process that should be maintained to avoid dangerous incidents. For the AC drive
system, the safe state is defined as activated STO function.
Service
A user level for accessing the Advanced safety option board functions. Identified via a password. In this
user level, it is not possible to verify a parameter file or change passwords.
SFRT
Safety Function Response Time
SRP/CS
Safety-Related Part of a Control System
AQ319736045637en-000101 / DPD01798 | 17Danfoss A/S © 2021.06
Introduction
VACON® NXP Advanced Safety Options
Operating Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON OPTEA and is the answer not in the manual?

Danfoss VACON OPTEA Specifications

General IconGeneral
BrandDanfoss
ModelVACON OPTEA
CategoryDC Drives
LanguageEnglish

Related product manuals