6.2.3 Cleaning the Photoelectric Sensor
If your application uses the photoelectric sensor option as a hardware trigger, be sure to
clean the photoelectric sensor periodically as outlined below.
1. Turn off the product transport.
2. Turn off the DM3610 by disconnecting the power source.
3. Clean the photoelectric sensor’s lens using the denatured alcohol solution and a
cotton swab or lens paper.
4. Clean the reflector using the denatured alcohol solution and a cotton swab or lens
paper.
5. Verify photoelectric sensor operation.