Chapter 7 Troubleshooting
PAGE 74
7-2-3. A.03: TOOL ID Error
Indication
Description/Cause
Recovery Method
A.03-01
ID Data Error
There is an error in the ID data in
the preamplifier.
1. Inspect the tool cable.
2. Breaking or malfunction of the tool cable or
the tool may have occurred.
A.03-02
Tool Type Error
The system parameters D-No. 100
“Connected Tool No.” and D-No.
200 “Unit Setup Tool No.” differ.
1. Set D-No. 200 to the same value as the Tool
No. D-No. 100 of the system parameters
(SYS).
2. Breaking or malfunction of the tool cable or
the tool may have occurred.
A.03-03
Tool Not Connected
The tool is not connected.
1. Inspect the tool cable.
2. Breaking or malfunction of the tool cable or
the tool may have occurred.
A.03-04
Tool Communication Error
An error occurred in the
communication between the tool
preamplifier and the Unit.
A.03-05
Watchdog Timer Error
Communication between tool
preamplifier and controller failed.
*When the Controller software
version V1.203 or lower, A.03-04 is
displayed.
1. Turn the control power OFF and then turn
ON the power again after waiting for at least
5 minutes.
2.Breaking or malfunction of the tool cable or the
Unit may have occurred.
S0140185-H