EasyManua.ls Logo

DDK HFC3000II - 9-1. Common specifications

DDK HFC3000II
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 External Interface
PAGE 9-2
9-1. Common specifications
9-1-1. Fieldbus I/O signal specifications
(1) Input signal specification[PLC HFC3000]
The input signal becomes the fixed layout.
Word
Byte
Singnal Name
Connection
Contents
No.
Bit#
No.
Bit#
IN
No.01
0
IN
No.01
0
Unused
NO
Always off.
1
1
Unused
NO
Always off.
2
2
Unused
NO
Always off.
3
3
Unused
NO
Always off.
4
4
BANK SELECT
NO
Fieldbus message bank reshuffling BIT.
In the case of CC-Link the output top position of the
message Can change it.
5
5
Unused
NO
Always off.
6
6
RESET
NO
Execute the following operation by setting this signal
to “ON.
Stop tightening process.
Set the PLC I / O fastening result signal of the
controller to OFF.
Delete the entered ID data.
7
7
Unused
Always off.(V1.300)
ID SELECT
ENABLE
NO
WORK number selection by input ID becomes enable by
setting this signal to ON(V1.309)
8
IN
No.02
0
Unused
NO
Always off.
9
1
Unused
NO
Always off.
10
2
Unused
NO
Always off.
11
3
Unused
NO
Always off.
12
4
Work Select Bit0
NO
Select the Parameter No.1~64 at Work Select 0~5.
13
5
Work Select Bit1
NO
14
6
Work Select Bit2
NO
15
7
Work Select Bit3
NO
IN
No.02
0
IN
No.03
0
STOP
NO or NC
Emergency stop
1
1
RESET
NO
It has the same function as the above RESET signal.
2
2
REVERSE
NO
Spindle will reverse(CCW) while active
3
3
START
NO
Starts fastening cycle
4
4
PROGRAM
NO
Bypass the unit
5
5
SELF CHECK
SKIP
NO
Skip self-check function
6
6
Unused
NO
Always off.
7
7
Unused
NO
Always off.
8
IN
No.04
0
Unused
NO
Always off.
9
1
Unused
NO
Always off.
10
2
Unused
NO
Always off.
11
3
Work Select Bit5
NO
Work Select 5.
12
4
BATCH OK RESET
NO
Initialize the number of cycle count to 0.
13
5
Work Select Bit4
NO
Work Select 4.
14
6
Unused
NO
Always off.
15
7
Unused
NO
Always off.
* Work Select Bits 0 to 5 are enabled with the system parameter: SYS.034 [00xxx1].
(Continued on next page)
S0140185-H

Table of Contents