EasyManua.ls Logo

DDK HFC3000II - Page 178

DDK HFC3000II
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 External Interface
PAGE 9-4
(2) Output signal specification[HFC3000→PLC]
The output signal becomes the fixed layout.
Word
Byte
Singnal Name
Connection
Contents
No.
Bit#
No.
Bit#
OUT
No.01
0
OUT
No.01
0
END
NO
Outputs when N/R operation ends.
1
1
ACCEPT
NO
Outputs when fastening result OK.
2
2
REJECT
NO
Outputs when fastening result NG.
3
3
MANREV
NO
Turned on when Start a reversal by manual operation.
The next clamping starts or is off in RESET,PROGRAM.
4
4
BANK OUTPUT
NO
The lapel output of fieldbus message bank reshuffling BIT.
5
5
BATCH OK
NO
Outputs when fastening result Total OK
6
6
Fastening Result
Data Available
NO
Outputs when N/R operation ends.
7
7
CF ERROR
NO
With the CF card option attached, within the following
conditions,
It turns ON when either one is satisfied.
· CF card not inserted
· CF card remaining capacity is 1% or less (~ V1.209)
· CF card remaining capacity is less than 20MB (V1.210 ~)
8
OUT
No.02
0
Work OUTPUT Bit4
NO
Outputs echo of work select 4~5.
9
1
Work OUTPUT Bit5
NO
10
2
1ST Time Reject
NO
Outputs when the fastening time is out of the range of the 1ST
time High and Low limits.
11
3
2ND Time Reject
NO
Outputs when the fastening time is out of the range of the
2ND time High and Low limits.
12
4
Work OUTPUT Bit0
NO
Outputs echo of work select 0~3.
13
5
Work OUTPUT Bit1
NO
14
6
Work OUTPUT Bit2
NO
15
7
Work OUTPUT Bit3
NO
OUT
No.02
0
OUT
No.03
0
REJECT
NO
Outputs when fastening result NG.
1
1
ACCEPT
NO
Outputs when fastening result OK.
2
2
ABNORMAL
NO
Outputs when system abnormality occurs.
3
3
READY
NO
Outputs when system ready condition.
4
4
BUSY
NO
Outputs during fastening or reverse operation.
5
5
TQ HI REJECT
NO
Outputs when the fastening torque is out of the range of the
Peak, Final, and sung torque High limits.
SNUG HI REJECT
6
6
TQ LO REJECT
NO
Outputs when the fastening torque is out of the range of the
Peak, and Final torque Low limits.
7
7
PROGRAM
OUTPUT
NO
Outputs echo of PROGRAM.
8
OUT
No.04
0
ANG HI REJECT
NO
Outputs when the fastening angle is out of the range of the
Final and DIFF angle High limits.
DIFF HI REJECT
9
1
ANG LO REJECT
NO
Outputs when the fastening angle is out of the range of the
Final and DIFF angle Low limits.
DIFF LOW REJECT
10
2
RATE1 HI REJECT
NO
Outputs when the fastening rate is out of the range of the
rate1 High limits.
11
3
RATE 1 LO REJECT
NO
Outputs when the fastening rate is out of the range of the
rate1 Low limits.
12
4
RATE 2 HI REJECT
NO
Outputs when the fastening rate is out of the range of the
rate2 High limits.
13
5
RATE 2 LO REJECT
NO
Outputs when the fastening rate is out of the range of the
rate2 Low limits.
14
6
RATE 3 HI REJECT
NO
Outputs when the fastening rate is out of the range of the
rate3 High limits.
15
7
RATE 3 LO REJECT
NO
Outputs when the fastening rate is out of the range of the
rate3 Low limits.
(Continued on next page)
S0140185-H