Chapter 6 Description of Operations
PAGE 6-28
4. Fastening Time High Limit Judgment
High limit 1ST time NG
Cause: Tapping fault of object of fastening, bolt thread fault
Detachment of socket
High limit 2ND time NG
Cause: Elongation of bolt
Cutting of bolt
Detachment of socket
5. Rundown Revolutions High Limit Judgment
Rundown Revolutions High Limit NG
Cause: Bolt fault
Detachment of socket
6. Others
Start Lever Off NG
Cause: Release the start lever
Gyro Stop NG
Cause: Gyro swing detection worked safety stop