EasyManuals Logo

Dell Command Line Interface User Manual

Dell Command Line Interface
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
164 Using the Storage Management Service
omconfig Unassign Dedicated Hot Spare
Use the following omconfig command syntax to unassign one or more physical disks that were previously
assigned as a hot spare to a virtual disk.
Complete Syntax
omconfig storage vdisk action=assigndedicatedhotspare controller=id
vdisk=id pdisk=<PDISKID> assign=no
where id is the controller ID and virtual disk ID. The <PDISK> variable specifies the physical disk.
To obtain the values for the controller, virtual disk, and physical disk, enter omreport storage controller
to display the controller IDs and then enter omreport storage vdisk controller=ID and omreport storage
pdisk controller=ID to display the IDs for the virtual disks and physical disks attached to the controller.
Example Syntax
In this example, you are unassigning physical disk 3 on connector 0 of controller 1 as a dedicated hot
spare to virtual disk 4. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 pdisk=0:3 assign=no
Example for SAS Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 pdisk=0:2:3 assign=no
omconfig Check Consistency
Use the following omconfig command syntax to initiate a check consistency on a virtual disk. The check
consistency task verifies the virtual disk’s redundant data.
Complete Syntax
omconfig storage vdisk action=checkconsistency controller=id vdisk=id
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these
values, enter omreport storage controller to display the controller IDs and then enter omreport storage
vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example Syntax
For example, to run a check consistency on virtual disk 4 on controller 1, enter:
omconfig storage vdisk action=checkconsistency controller=1 vdisk=4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Command Line Interface and is the answer not in the manual?

Dell Command Line Interface Specifications

General IconGeneral
BrandDell
ModelCommand Line Interface
CategoryNetwork Card
LanguageEnglish

Related product manuals