What does 'Used TEST DEVICE' mean on Diesse cube 30 touch?
- KKathleen HughesSep 7, 2025
The 'Used TEST DEVICE' message means that the test Device in use is empty. Obtain a new test device.
What does 'Used TEST DEVICE' mean on Diesse cube 30 touch?
The 'Used TEST DEVICE' message means that the test Device in use is empty. Obtain a new test device.
What to do if the Diesse cube 30 touch shows 'USB device not found'?
If the instrument does not recognize the USB device, try removing and reinserting the device. If that doesn't work, replace the USB device.
What does 'Caution! āNā tests remain' mean on Diesse cube 30 touch?
This caution message indicates that the number of remaining tests is less than 50. Be sure to reload the device as soon as possible with a new test device.
What to do when Diesse cube 30 touch says 'Exam not available Reloading required'?
This message indicates that there are zero tests remaining. Follow the instructions for reloading the instrument with a new test device.
What does 'Anomalous test tube Err (15)' mean on Diesse cube 30 touch?
This error may be due to significant sedimentation with a low volume of blood. Check for the presence of clumps or clots and try to repeat the test.
How to resolve interference from the label on Diesse cube 30 touch Laboratory Equipment?
If the label is causing interference, try to remove or reposition the label and then repeat the test.
What to do if Diesse cube 30 touch shows 'Cycle interrupted Err (16)'?
If the run was aborted before the second sample reading, resulting in the 'Cycle interrupted Err (16)' error, repeat the analysis, making sure not to interrupt the cycle before the analysis is complete.
What does 'Error Removed tube Err (11)' mean on Diesse cube 30 touch and how to fix it?
The 'Error Removed tube Err (11)' appears if the test tube is removed during the cycle. To resolve this, repeat the test for that sample.
What does Err (2) (3) mean on Diesse cube 30 touch Laboratory Equipment?
Err (2) (3) indicates that the bottom of the test tube was not identified. Check that the test tube in use is compatible with the instrument and that it has been inserted correctly. Visually inspect the sample for presence of clumps or clots.
What to do if Diesse cube 30 touch Laboratory Equipment displays 'FATAL ERROR! MOTOR FAIL!'?
This error indicates an engine problem with a component. In the message on the screen, press the 'OK' button, remove all samples from the plate, and restart the instrument. If the problem persists, contact Technical Assistance.
Specifies the primary use and application of the CUBE 30 TOUCH instrument.
Provides an overview of the CUBE 30 TOUCH instrument, its design, and capabilities.
Highlights critical safety precautions and potential hazards associated with instrument use.
Specifies the required personal protective gear for safe operation and handling.
Describes the steps for safely cleaning and decontaminating the instrument.
Explains the procedure for updating the instrument's software to the latest version.
Provides guidelines for safely transporting and handling the instrument.
Outlines the complete steps for setting up and installing the instrument.
Details the procedure for replacing the instrument's fuses if they blow.
Describes the correct procedures for preparing blood samples for analysis.
Initiates the process of running an ESR analysis cycle on the instrument.
Details how to load test tubes into the instrument's carousel.
Explains the steps to begin an ESR measurement cycle after loading samples.
Describes how to add samples to the instrument during an ongoing test run.
Explains how to view and interpret the ESR analysis results.
Provides access to service menus and firmware information.
Details the process for registering quality control materials not supplied by the manufacturer.
Explains how to run quality control samples on the instrument.
Addresses issues and warnings related to operating temperatures outside the specified limits.
| Brand | Diesse |
|---|---|
| Model | cube 30 touch |
| Category | Laboratory Equipment |
| Language | English |