User manual DPC Touch V2 DOC.60352-11/20
19
3.3.1 Operating - Management of Interface
Parameters
Description
Range
Default
Value
Tool Selection
Select one of the following option:
- GX, GY, DO, GA: DOGA low voltage
tools (XS-40D, XS-38D, XT-30D,
XS-35D, XT-35D)
- DC tools: all electric digital control
tools equipped with 24V I/O signals
-
DC
tools
Screws
counting
up/down
This parameter manages the counting
display. Turn it ON to count up (1,2,3,…)
or OFF to count down (...,3,2,1)
ON/OFF
ON
Screws
counting per
step/job
This parameter manages the counting
display. Turn it ON to display counting
separately for each step or OFF to
display counting for the whole job.
ON/OFF
ON
Torque
selection by
binary outputs
Selection of tightening presets for each
position is done via Torque selection
outputs. These outputs can function in
binary logic or in direct logic (one output
per preset).
ON/OFF
ON
Job selection
by binary
inputs
Selection of Jobs of DPC Touch can be
done via Job selection inputs. These
inputs can function in binary logic or in
direct logic (one input per job).
ON/OFF
ON
Default job
number
The default job is the job that
automatically runs when the DPC Touch
powers up. If the default job number is
set to 0, the DPC Touch will not run any
jobs on start up.
NOTE: Job selection via inputs has a
higher priority.
0 - 255
1