3.3.4 Operating - Management of NG tightenings
Numbers of
retightenings
on a position
Maximum number of attempts to
rework a NG fastening. If the maximum
number of attempts is reached the
current position can be skipped or
Job/Step can be reset according to
parameters selected.
NOTE: this parameter is not effective in
non-sequential assembly mode.
Allows automatic skipping of a NG
tightening if rework is not allowed or if
rework wasn’t successful.
Fastening NG
signal if
position
skipped
If turned ON, Fastening NG signal will
be provided when a position is skipped
automatically, by Skip button on the
operating screen or by external input. If
turned OFF, Fastening OK signal will be
provided.
Alarm can be reset automatically after
the specified delay. If delay is equal to 0
than reset has to be done manually or