User manual DPC Touch V2 DOC.60352-11/20
94
8.4 Modbus TCP/IP address - Event monitoring
Adr.
Status
Function Code
3300
Event no
0x04
3301
Event occur year
0x04
3302
Event occur month
0x04
3303
Event occur day
0x04
3304
Event occur hour
0x04
3305
Event occur minute
0x04
3306
Event occur second
0x04
3307
Job no
0x04
3308
Step no
0x04
3309
Step type
0: Empty step
1: Fastening
2: Input
3: Output
4: Delay
5: Message
0x04
3310
Action type
0: Empty
1: Job select
2: Job finish
3: Job reset
4: Step select
5: Step reset
6: Error
7: Reset
8: Emergency
9: Skip 10: Back
11: Fasten
12: Barcode
0x04

Table of Contents