9.4.1 Dismantling of the shaft detent
• Unscrew the lid of the shaft detent from the valve block. For this
purpose, use the special tool for fiber optics.
Fig 176: Lid of the shaft detent
1 Lid
2 Special fiber optics tool
• Remove the shaft detent from the body.
Fig. 277: Removing the detent from the body
9.4.2 Installation of the shaft detent
• Lightly grease the O-ring of the shaft detent with special grease
(see chapter 10 in “Auxiliary materials for maintenance”).
• Insert the shaft detent.
• Screw in the lid of the shaft detent with the special fiber optics tool.