EC - Rotating Atomizer with External Charging
Version:: 07 • As of:: 01/2020
10.2 Separating the atomizer from the flange package
Personnel:
- Assembly personnel
Protective equipment:
- Protective work wear
- Protective glasses
- Protective gloves
- Safety boots
Procedure:
• Release the clamping screw. Meanwhile, hold the atomizer tight.
• Remove the atomizer from the flange.
• Remove three plastic screws on the electrode ring.
• Pull out electrode ring.
10.3 Dismantling of the atomizer
Personnel:
- Assembly personnel
Protective equipment:
- Protective work wear
- Protective glasses
- Protective gloves
- Safety boots
Process:
• Dismantle the atomizer into individual parts.