- Rotating Atomizer with External Charging
Version:: 07 • As of:: 01/2020
Paint - outflow rate
Maximum 700ml/min
recommended operating range 80 – 350ml/min
Rinsing agent - outflow rate
Detergent
for quick purging via nozzle 700ml/min ±50ml/min
Temperature and humidity
Basic limits in the paint environment
If the atomizer is not operated, the following limits have to be complied
with unconditionally.
Ambient temperature 10 – 40 °C
Relative humidity 35 – 90%
Outside these limits, the atomizer will be damaged.
Parameters when operating
Temperature 23 °C ±3 °C
Relative humidity 65% ±5%
Velocity of air flow in the painting booth 0.2 – 0.7m/s
6.3.2 High voltage
I
konstant
max. 400µA
Resistances
Resistance between paint nozzle/paint pipe and connecting port
Test voltage 4 – 24V
Resistance value ≤ 10Ω
Resistance between shaft (on turbine side) and connecting port
(with motor bearing air)
Test voltage 50V
Resistance < 0.1MΩ
Grounding of the work piece
Test voltage 1,000V
Resistance value < 1MΩ