EasyManua.ls Logo

Dorr EcoBell2 SL EC - 6.3 Operating Parameters

Dorr EcoBell2 SL EC
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual
© Dürr Systems AG
70 / 156
EcoBell2 SL EC
- Rotating Atomizer with External Charging
Operation
Doc
ument No.: MRA00001EN
Version:: 07 As of:: 01/2020
The design of the workpiece holder must ensure that the work pieces
remain grounded during the coating. The ground-leakage resistance
at a test voltage of up to 1000V may not exceed 1 MΩ.
6.2.7 Spray Pattern
Damage to the bell disk or the shaping air ring have a negative effect
on the spray pattern.
If during the operation of the atomizer, changes are noticed that
indicate damage or inadmissible performance, the atomizer must
immediately be taken out of service.
A T T E N T I O N
Risk of production disruption due to defective components
A poor paint job can be the result.
An atomizer with defective components must not be operated in any
case.
Never paint with a damaged or worn bell disk. Use bell disks from Dürr
Systems only.
Pos: 38 /INP/ Bell2/06_03 Be triebspa rameter_AA @ 57\ mod_15 04254437077 _20.docx @ 6205 43 @ 2553 555533 @ 1
6.3 Operating Parameters
Operating modes
- Exterior painting with high voltage
- Metallic painting with high voltage
- Plastic painting with high voltage
Speed of bell disk
Rotational speed, max. 70,000 ± 500 RPM
Usable speed range 8,000 70,000 RPM
Speed sensor reflector disk
Pulses per revolution of turbine shaft 4
Work areas
Working range EcoBell2 SL 15,000 55,000 RPM
Speed when flushing briefly (recommended) 40,000 45,000 RPM
Lowest braking speed 2,000min
-1