8.3 Behavior during faults
Should there be a fault, then kindly note the following instructions:
- Switch off the system and protect it against reconnection.
Enable "Maintenance" mode.
- Completely separate material supply and compressed air.
- Discharge the residual energy (earthing rod).
- Troubleshooting according to the fault table or as specified in the
control documentation.
Pos: 60 /INP/ Bell2/08_04 T abelle Störu ngsbehebun g_AA @ 39\mod_ 1408538917 259_20.d ocx @ 494532 @ 2 @ 1
8.4 Troubleshooting
Personnel:
- Assembly personnel
Protective equipment:
- Protective clothing
- Protective glasses
- Protective gloves
- Safety boots
The table below lists possible faults during the operation of the
atomizer. Possible causes and fixes are specified.
Type of fault Possible cause
9 and fix
Leakage Leaking seal between the components
- Assemble the atomizer correctly
Leaking hose
- Replace the hose on the flange assembly
Atomizer
not working correctly
Bell disk not installed
Missing bell disk
- Install the bell disk correctly
Damaged bell disk