User’s Manual xLogic SuperRelay
11
computer has no standard serial port.
xLogic: Ethernet module(type:ELC-Ethernet)
It is called Ethernet module, used to connect xLogic main modules in different places
to enormous Ethernet to buildup a huge monitoring and control system. It contains
DC and AC two types.
xLogic: SMS module(type:ELC-SMS)
ELC-SMS is kind of SMS module, through which SMS can be regarded as
expansion input by user to realize wireless remote control and it can send alarm
messages to user cell phones.
Communication / Network
xLogic offers different ways to communicate within the system.
RS485 port
The RS485 port is used for communication between the main module and various devices
or equipments which have the standard RS485 port .(only ELC-18 Series available, not
applied to ELC-12 series) Communicate using Modbus RTU protocol.
RS232 or USB port
If there is no network required and only one main module with some expansion modules
is needed for the application, the down- and upload of the project to and from the main
module happens over the standard RS232 or USB port. It allows system maintenance like
monitoring too.