11 Annex
11.3 Technical data
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com 175
11.3.2 DC1-12
Symbol
Unit
DC1-
122D3…
DC1-
124D3…
DC1-
127D0…
DC1-
127D0…
DC1-
12011…
DC1-
12015…
Main circuit
Feeder unit
Rated operating voltage U
e
V AC 230, single-phase
Mains voltage (50/60Hz) U
LN
V 200 (-10 %) - 240 (+10 %)
Input current I
LN
A 5 8.5 13.9 13.9 19.5 30.5
Mains frequency f
LN
Hz 50/60
Frequency range f
LN
Hz 48 - 62
Power section
Overload current for 60 s every 600 s I
L
A 3.45 6.45 10.5 10.5 15.75 22.5
Starting current for 2 s every 20 s I
L
A 4.03 7.53 12.25 12.25 18.38 26.25
Output voltage at U
e
U
2
V AC 230, 3-phase
Output frequency f
2
Hz 0 - 50 (max. 500)
Pulse frequency f
PWM
kHz 16 (adjustable 4 – 32) 8 (adjust-
able 4 - 24)
Frequency resolution (setpoint value) ΔfHz
0.1 0.1 0.1 0.1 0.1 0.1
Rated operational current
1)
I
e
A 2.3 4.3 7 7 10.5 15
Heat dissipation
Heat dissipation of rated operational
current
P
V
W 18.5 45.75 63 63 103.4 160
Efficiency η %
95 93.9 95.8 95.8 95.3 96
Maximum leakage current to earth (PE)
without motor
I
PE
mA 2.49 2.49 2.49 2.49 2.49 < 1
Fan, built-in
– ✓ ✓ ✓ ✓ ✓
Size
FS1 FS1 FS1 FS2 FS2 FS3
Motor feeder
Assigned motor output
at 230 V, 50 Hz P kW 0.37 0.75 1.5 1.5 2.2 4
at 220 - 240 V, 60 Hz P HP 0.5 1 2 2 3 5
Apparent power
Apparent power at rated operation
230 V
SkVA0.92 1.71 2.79 2.79 4.18 5.98
Apparent power at rated operation
240 V
SkVA
0.96 1.79 2.91 2.91 4.36 6.24