11 Annex
11.18 Sine filter
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com 219
11.18 Sine filter
Figure 124: Sine filter DX-SIN3…
The DX-SIN3… sine filter removes high-frequency components from the vari-
able frequency drive's output voltage (U
2
). This reduces the conducted and
radiated emission. The sine filter's output voltage has a sine wave shape
with a small superimposed ripple voltage.
The sinusoidal voltage's total harmonic distortion is typically 5 to 10%. This
reduces noise and losses in the motor.
Figure 125:Maximum permissible motor cable lengths
a Screened motor cable: U
2
230 V 200 m (656.17 ft); U
2
500 V 150 m (492.13 ft)
Unscreened motor cable: U
2
230 V 300 m (924.25 ft); U
2
500 V 200 m (656.17 ft
Figure 126: Derating values for deviating installation altitudes and ambient air tempera-
tures
For more information and technical data regarding
DX-SIN3… series sine filters, please consult instructional
leaflet IL00906001Z.
M
3 ~
DX-SIN3...
U
max
f
PWM
f
2
U2
l
e
u
k
l
L
0
0.5
0.6
0.7
0.8
0.9
1.0
1000 2000 3000 4000
h [m]
I
I
e
40
0.5
0.6
0.7
0.8
0.9
1.0
45 50 55
Iso. class F
ta [°C]
I
I
e
a