5 Parameters
5.1 Operating unit
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com 93
5 Parameters
5.1 Operating unit
The DC1 variable frequency drive's integrated keypad is designed to make it
easy to commission the drive and configure its parameters. The figure below
shows the elements that make up the DC1 variable frequency drive's keypad.
Figure 58: Operating unit view
Table 10: Keypad designations
View
Controls
(buttons)
Operating unit element Explanation
Six-digit 7-segment LED display
Motor starter with pre-selected operating direction if parameter P-12 = 1
(FWD) or P-12 = 2 (FWD / REV).
Note:
Enable with +24 V on control signal terminal 2 (DI1)
P-12 = 2: The first time it is pressed (commissioning, parameter reset),
a clockwise rotating field (FWD) will always be activated. Only after it is
pressed for a second time will the direction of the rotating field change to
a counterclockwise rotating field (REV). (The corresponding setting will be
retained even after the supply voltage is switched off.)
Stops the running motor if P-12 = 1 or P-12 = 2
Reset – Resetting after an error message
Activate parameter input (editing mode)
Activate parameter value, change (display value flashes)
Confirm (store) and activate configured value
Used to switch the display unit between Hz and rpm and A...
Increment numeric value or parameter number
Increase output frequency / motor speed if P-12 = 1 or P-12 = 2
Decrement numeric value or parameter number
Reduce output frequency / motor speed if P-12 = 1 or P-12 = 2