EasyManua.ls Logo

Eaton PowerXL DC1 Series - 3.5.4 Insulation test

Eaton PowerXL DC1 Series
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Installation
3.5 Electrical Installation
76 DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com
3.5.3.1 DC1-1D…Nx-…
Figure 51: Block diagram for DC1-1D…Nx-…
DC1-1D…Nx-… variable frequency drives have a voltage doubler circuit in their
internal DC link. When there is a power supply of 1 AC 110 - 115 V, a motor voltage
of up to 3 AC 230 V will be output.
FS2 devices allow for the connection of braking resistances.
DC+
BR
DC-
3 AC 230 V
WVU
M
3 ~
2
DI1
FWD
24 V
3
DI2
REV
4
DI3
AI2
FF1
5
+10 V Out
< 10 mA
10 V
6
AI1
DI4
f-Soll
7
0 V
1
+24 V Out
< 100 mA
L1/L
8
0...+10 V
< 20 mA AO
+24 V DO
f-Out
+
9
0 V
10
L2/N
VAR
11
RUN
6 A, 250 VAC
5 A, 30 VDC
CPU
0...+10 V
1 AC 110/115 V
50/60 Hz
PES
X1
PIN 8
(PIN2)
PIN 7
(PIN 1)
RS485
FS2
DC1-1D…Nx-… variable frequency drives do not have an
internal radio interference suppression filter.
An external radio interference suppression filter is required for
operation in accordance with EN 61800-3.

Table of Contents