TRSM0940 Service Procedures | VCS/VMS Auxiliary Section Assembly and Installation
18. Install the Bearing Inner Spacer on the Output Shaft.
19. Lay the Auxiliary Mainshaft Assembly on
its side.
20. Apply light coating of
transmission lubricant to the sur-
face of the synchronizer assembly.
21. Install
the Synchronizer Assembly on the Auxiliary
Mainshaft Assembly.