Protection
Password protection is used to protect access to the EMU device. The password is required to
access any data and log. In the case of missing password it is possible to restore device to factory
defaults, however all information will be lost.
PARAMETER DESCRIPTION
Enable password protection Activate password protection
Copyrights The string with author information
Contact info
The string with email address or phone number to allow contact
with password owner
Password The password
Oil pressure cut
Oil pressure cut strategy is used for engine protection in case of low oil pressure during engine
work. If the oil pressure for given RPM is lower than defined the engine will shut off. The minimal
oil pressure for given RPM is defined in the Oil Pressure Cut table.
PARAMETER DESCRIPTION
Oil pressure cut enable Activation of oil pressure protection strategy
Oil pressure start delay
The time after engine start up when the function is not active (time
required to build up oil pressure by the oil pump)
Oil pressure cut delay
The allowable time during the oil pressure is lower than the
pressure defined in Oil Pressure Cut table. After this time the
engine will shut off
Oil pressure restart time The time required to start the engine again
Page 117