Emerson Process Management GmbH & Co. OHG 1-15
1
Techn. Description
X-STREAM X2FD
Instruction Manual
HASXMDE-IM-EX
01/2015
NDIR/UV/VIS Thermal Conductivity (TCD)
Detection limit (4 σ)
1 4
1 % 1 %
Linearity
1 4
1 %
1 %
Zero-point drift
1 4
2 % per week 2 % per week
Span (sensitivity) drift
1 4
0.5 % per week 1 % per week
Repeatability
1 4
1 %
1 %
Response time (t
90
)
3
4 s t
90
7 s
5
15 s t
90
30 s
6
Permissible gas ow 0.2–1.5 l/min. 0.2–1.5 l/min. (
+
0.1 l/min)
In uence of gas ow
1 4
0.5 % 1 %
12
Maximum gas pressure
8 9
1500 hPa abs. ( 7 psig) 1500 hPa abs. ( 7 psig)
In uence of pressure
2
At constant temperature 0.10 % per hPa 0.10 % per hPa
– With pressure compensation
7
0.01 % per hPa 0.01 % per hPa
Permissible ambient temperature
10
0 (-20) to +50 °C (32 (-4) to 122 °F) 0 (-20) to +50 °C (32 (-4) to 122 °F)
In uence of temperature
1 14
(at constant pressure)
– On zero point 1 % per 10 K 1 % per 10 K
– On span (sensitivity) 5 % (0 to +50 °C / 32 to 122 °F) 1 % per 10 K
Thermostat control
6 13
none / 60 °C (140 °F)
5
none / 60 °C (140 °F)
11
Warm-up time
6
15 to 50 minutes
5
approx. 50 minutes
Note! 1 psi = 68.95 hPa
1
Related to full scale
2
Related to measuring value
3
From gas analyzer inlet at gas ow of 1.0 l/min
(electronic damping = 0 s)
4
Constant pressure and temperature
5
Dependent on integrated photometer bench
6
Depending on measuring range
7
Pressure sensor is required
8
Special conditions for > 1100 hPa abs. (1.5 psig)
9
Limited to atmospheric if internal sample pump
10
Temperatures below 0 °C (-4 °F) with thermostat
control only
11
Thermost. controlled sensor: 75 °C (167 °F)
12
Flow variation within
±
0.1 l/min
13
Optional thermostatically controlled box with
temperature 60 °C (140 °F)
14
Temperature variation:
10 K per hour
1.8 Measurements Speci cations
Standard Performance Speci cations
Note! 1 psi = 68.95 hPa
1
If installed in series to another measurement system, e. g. IR channel
2
Special conditions for > 1100 hPa abs. (1.5 psig)
Trace Moisture (tH
2
O)
Measurement range -100 to -10 °C dew point (0–3000 ppm)
Measurement accuracy ±2 °C dew point
Repeatability 0.5 °C dew point
Response time (t
95
) 5 min (dry to wet)
Operating humidity 0 to 100 % r.h.
Sensor operating temperature -40 to +60 °C
Temperature coef cient Temperature compensated across operating temperature range
Operating pressure
Depending on sequential measurement system, see analyzer speci cation
1
max. 1500 hPa abs / 7 psig
2
Flow rate
Depending on sequential measurement system, see analyzer speci cation
1
0.2 to 1.5 l/min
Tab. 1-2: NDIR/UV/VIS, TCD - Standard Measurement Performance Speci cations
Tab. 1-3: Trace Moisture - Standard Measurement Performance Speci cations
Note! Do not calibrate, see special calibration notes in the X-STREAM X2 instruction manual!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson ROSEMOUNT Xstream X2 Series and is the answer not in the manual?

Emerson ROSEMOUNT Xstream X2 Series Specifications

General IconGeneral
BrandEmerson
ModelROSEMOUNT Xstream X2 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals