Emerson Process Management GmbH & Co. OHG 4-3
4
Maintenance
X-STREAM X2FD
Instruction Manual
HASXMDE-IM-EX
01/2015
Modi cations made on the electrical appara-
tus affecting the integrity of the type of protec-
tion or the temperature of the apparatus shall
be permitted only if the modi ed apparatus is
resubmitted to a testing station.
4.1 Veri cations and Tests
4.1 Veri cations and Tests
4.1.1 Routine Tests on Analyzer
The following tests shall be performed on a
regular basis:
4.1.1.1 Visual Inspection
The instrument shall be visually checked for
damages to the enclosure, ange and exter-
nal analyzer components.
Especially take care that there are no scrat-
ches on the anges surfaces!
See section 4.1.1.2 for more information on
how to verify the anges‘ compliances with
the certi cation requirements, if the results
of the visual inspection is not clear.
EXPLOSION HAZARD
Do not continue to operate a damaged analyzer!
Call for service!
Violation may cause an explosion and/or personal injury or death!
In the case of repairs affecting the type of
protection, the parts which have been re-
paired should be subjected to new routine
veri cations and tests. These tests need not
necessarily be made by the manufacturer.
Contents
4.1 Veri cations and Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2 Replacement of Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.3 Vapor Recovery Application - Special Information . . . . . . . . . . . . . . . . . . . . . . 4-9
4.4 Perform a calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Compare the installed components with the
list shown in section 4.2 of this manual: Unau-
thorized replacement of parts is not permitted,
may affect the safety of the analyzer and
violates the certi cation!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson ROSEMOUNT Xstream X2 Series and is the answer not in the manual?

Emerson ROSEMOUNT Xstream X2 Series Specifications

General IconGeneral
BrandEmerson
ModelROSEMOUNT Xstream X2 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals