Address Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
9309…
9312
6617…
6624
Setup.Measurement.XIntf.Linear-
References1
Float R/W
Cross interfere linearization references1..4 for
comp1
9313…
9316
6625…
6632
Setup.Measurement.XIntf.Linear-
PolyCoeffs1
Float R/W
Cross interfere linearization references1..4 for
comp1
9331…
9334
6661…
6668
Setup.Measurement.XIntf.Signal-
Values2
Float RO Cross interfere signal values1..4 for comp2
9335…
9338
6669…
6676
Setup.Measurement.XIntf.Interfer-
eFactors2
Float R/W Cross interfere factors1..4 for comp2
9339…
9342
6677…
6684
Setup.Measurement.XIntf.Linear-
References2
Float R/W
Cross interfere linearization references1..4 for
comp2
9343…
9346
6685…
6692
Setup.Measurement.XIntf.Linear-
PolyCoeffs2
Float R/W
Cross interfere linearization references1..4 for
comp2
9361…
9364
6721…
6728
Setup.Measurement.XIntf.Signal-
Values3
Float RO Cross interfere signal values1..4 for comp3
9365…
9368
6729…
6736
Setup.Measurement.XIntf.Interfer-
eFactors3
Float R/W Cross interfere factors1..4 for comp3
9369…
9372
6737…
6744
Setup.Measurement.XIntf.Linear-
References3
Float R/W
Cross interfere linearization references1..4 for
comp3
9373…
9376
6745…
6752
Setup.Measurement.XIntf.Linear-
PolyCoeffs3
Float R/W
Cross interfere linearization references1..4 for
comp3
9391…
9394
6781…
6788
Setup.Measurement.XIntf.Signal-
Values4
Float RO Cross interfere signal values1..4 for comp4
9395…
9398
6789…
6796
Setup.Measurement.XIntf.Interfer-
eFactors4
Float R/W
Cross interfere factors1..4 for comp4
9399…
9402
6797…
6804
Setup.Measurement.XIntf.Linear-
References4
Float R/W
Cross interfere linearization references1..4 for
comp4
9403…
9406
6805…
6812
Setup.Measurement.XIntf.Linear-
PolyCoeffs4
Float R/W
Cross interfere linearization references1..4 for
comp4
9421…
9424
6841…
6848
Setup.Measurement.XIntf.Signal-
Values5
Float RO Cross interfere signal values1..4 for comp5
9425…
9428
6849…
6856
Setup.Measurement.XIntf.Interfer-
eFactors5
Float R/W Cross interfere factors1..4 for comp5
9429…
9432
6857…
6864
Setup.Measurement.XIntf.Linear-
References5
Float R/W
Cross interfere linearization references1..4 for
comp5
9433…
9436
6865…
6872
Setup.Measurement.XIntf.Linear-
PolyCoeffs5
Float R/W
Cross interfere linearization references1..4 for
comp5
9491…
9498
6981…
6996
Service.Measurement.Simulation.
SimXSPMuxValue1
Float R/W simulation value for XSP's multiplexer value1..8
9501…
9503
7001…
7006
Service.Measurement.Lin.TableX-
Values1
Float R/W Linearization table X-Values of comp1
9531…
9533
7061…
7066
Service.Measurement.Lin.Tab-
leYValues1
Float R/W Linearization table Y-Values of comp1