4.4 Degree of protection
The devices fulfill all the requirements for NEMA 4X (IP 67). Compliance with the follow-
ing points is mandatory following installation in the field or servicing, in order to ensure
that NEMA 4X (IP 67) protection is maintained:
The housing seals must be clean and undamaged when inserted into their grooves.
The seals must be dried, cleaned or replaced if necessary.
All threaded fasteners and screw covers must be firmly tightened.
The cables used for connection must be of the specified outside diameter
(see Page 122).
Firmly tighten the conduit entries (Fig. 40).
The conduit must loop down before they enter the conduit entries (“water trap”,
Fig. 40). This arrangement prevents moisture penetrating the entry. Always install the
measuring device in such a way that the conduit entries do not point up.
Remove all unused conduit entries and insert plugs instead.
Do not remove the grommet from the conduit entry.
Fig. 40: Installation instructions, conduit entries
"
Caution:
Do not loosen the threaded fasteners of the Promag sensor housing, as otherwise the
degree of protection guaranteed by Endress+Hauser no longer applies.
!
Note:
The Promag W and Promag P sensors can be supplied with NEMA 6P (IP 68) rating
(permanent immersion in water to a depth of 10 ft/3 meters). In this case the transmitter
must be installed remotely from the sensor.