Trouble-shooting Proline Promass 83 PROFIBUS DP/PA
124 Endress+Hauser
042 S TRANSM. SW DAT
$ # 042
0x0F BAD Device Failure Constant T-DAT data
inconsistent
Cause:
System error. Error accessing the calibration values
stored in the T-DAT.
Remedy:
Verify that the T-DAT is correctly plugged into the
amplifier board, → Page 139 ff. Replace T-DAT if
defective. Spare parts → Page 137 ff. Check the
spare part set number to ensure that the new,
replacement DAT is compatible with the measuring
electronics.
Replace measuring electronics boards if necessary.
Spare parts → Page 137 ff.
061 S HW F-CHIP
$ # 061
0x0F BAD Device Failure Constant F-CHIP failure Cause:
Transmitter F-Chip
F-Chip is defective
F-Chip is not plugged into the I/O board or is
missing.
Remedy:
Replace the F-Chip.
Accessories
Plug the F-Chip into the I/O board
121 S A/C COMPATIB.
$ # 121
0x0F BAD Device Failure Constant Amplifier and
I/O board only
partially
compatible
Cause:
System error. Due to different software versions,
I/O board and amplifier board are only partially
compatible (possibly restricted functionality).
!
Note!
• This message is only listed in the error history.
• Nothing is displayed on the display.
Remedy:
Module with lower software version has either to be
actualized by ToF Tool – Fieldtool with the required
software version or the module has to be replaced.
Spare parts → Page 137 ff.
205 S LOAD T-DAT
! # 205
0x0F BAD Device Failure Constant Save to T-DAT
failed
Cause:
System error. Data backup to T-DAT failed, or error
when accessing the calibration values stored in the
T-DAT.
Remedy:
1. Verify that the T-DAT is correctly plugged into
the amplifier board, → Page 139 ff. Replace T-
DAT if defective. Spare parts → Page 137 ff.
Check the spare part set number to ensure that
the new, replacement DAT is compatible with
the measuring electronics.
2. Replace measuring electronics boards if
necessary.
Spare parts → Page 137 ff.
No. Device status message
(local display)
PROFIBUS measured value status
Adv. diagnosis
message in
PROFIBUS
master
Cause/remedy
Quality code (HEX)
Quality status
Quality substatus
Limits