Proline Promass 83 PROFIBUS DP/PA Technical data
Endress+Hauser 167
Material Transmitter housing:
• Compact housing: stainless steel 1.4301/304
• Compact housing: powder coated die-cast aluminium
• Wall-mount housing: powder coated die-cast aluminium
• Remote field housing: powder-coated die-cast aluminium
Sensor housing / containment:
Promass F:
Acid- and alkali-resistant outer surface
DN 8...50: stainless steel 1.4301/304
DN 80...250: stainless steel 1.4301/304 and 1.4308/304L
Promass M:
Acid- and alkali-resistant outer surface
DN 8...50: steel, chemically nickel-plated
DN 80: stainless steel
Promass E, A, H, I:
Acid- and alkali-resistant outer surface
Stainless steel 1.4301/304
Connection housing, sensor (remote version):
• Stainless steel 1.4301/304 (standard)
• powder coated die-cast aluminium (high-temperature version and version for heating)
Process connections
Promass F:
• Flanges EN 1092-1 (DIN 2501) / ANSI B16.5 / JIS B2238 * stainless steel 1.4404/316L
• Flanges EN 1092-1 (DIN 2501) / ANSI B16.5 / JIS B2238 * Alloy C-22 2.4602/N 06022
• Flange DIN 11864-2 Form A (flat flange) * stainless steel 1.4404/316L
• Hygienic coupling DIN 11851 / SMS 1145 * stainless steel 1.4404/316L
• Couplings ISO 2853 / DIN 11864-1 * stainless steel 1.4404/316L
• TriClamp (OD-tubes)* stainless steel 1.4404/316L
Promass F (high-temperature version):
• Flanges EN 1092-1 (DIN 2501) / ANSI B16.5 / JIS B2238 * stainless steel 1.4404/316L
• Flanges EN 1092-1 (DIN 2501) / ANSI B16.5 / JIS B2238 * Alloy C-22 2.4602 (N 06022)