AcuLaser C2800/C2800D/C3800/C3800D Revision C
DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 374
Confidential
SWITCH ASSY SIZE
1. Disconnect the connector (P/J4211) that is connected to the SWITCH ASSY SIZE.
2. Remove the clamp, which is connected to the SWITCH ASSY SIZE, together with the harness.
3. Remove the screw (silver, self-tapping, 8 mm) that secures the SWITCH ASSY SIZE to the GUIDE
TRAY R 550.
4. Pull out the guide pin on the bottom of the SWITCH ASSY SIZE from the square holes on the
GUIDE TRAY R 550, pull out the two guide pins from the hole on the GUIDE TRAY R 550, and
remove the SWITCH ASSY SIZE.
C
Kmy03236E
2)
3)
4)
1) (J4211)
SWITCH ASSY SIZE
PWBA FEED-H
1. Disconnect all the connectors on the PWBA FEED-H. (P/J419, P/J420, P/J421, P/J422)
2. Remove the three screws (silver, 6 mm) that secure the PWBA FEED-H to the FRAME ASSY OPT.
3. Remove the PWBA FEED-H from the FRAME ASSY OPT.
D
Kmy03237E
1)
(P/J419)
(P/J420)
(P/J421)
(P/J422)
2)
3)
2)
2)
PWBA FEED-H