S
ervice engineer require message
1
07
SERVICE REQ. 00010014: PRESSURE DEFECTIVE ERROR
o
Problem.
n
It is defective the pressure detection error or pressure sensor by providing system
motor step-out.
n
Pressure sensor is in trouble.
n
Providing motor defective, motor connector or motor cable disconnected
n
Air pressure reeked between providing pump and I/C cartridge
o Solution
n
Regulator valve solenoid exchange
n
Supply system motor exchange
n
Sensor exchange
n
C362DRV board exchange
SERVICE REQ. 00010015: LIQUID SENSOR OVERFLOW (K)
SERVICE REQ. 00010016: LIQUID SENSOR OVERFLOW (C)
SERVICE REQ. 00010017: LIQUID SENSOR OVERFLOW (M)
SERVICE REQ. 00010018: LIQUID SENSOR OVERFLOW (LC)
SERVICE REQ. 00010019: LIQUID SENSOR OVERFLOW(LM)
SERVICE REQ. 0001001A: LIQUID SENSOR OVERFLOW(Y)
o
Problem
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
o Solution
n
I/C valve solenoid exchange
n
C362DRV board exchange
n
Printhead exchange
SERVICE REQ. 0001001B: HEAD DRIVER (TG) TEMPERATURE
ERROR
o
Problem
Head failure or head cable splicing defective/breaking of wire
o Solution
n
Head cable joint
n
Head Assy exchange
SERVICE REQ. 0001001C: FS ORIGIN (SUCTION FAN SHUTTER
HOME POSITION) ERROR
o
Problem
Starting point detection error or shutter starting point sensor defective o treatment by
shutter motor step-out.
o Solution
n
Adsorption fan shutter motor exchange
n
C362DRV board exchange
n
Shutter home point sensor exchange
n
Shutter mechanism check
SERVICE REQ. 0001001D: CR SERVO PARAMETER ERROR
o
Problem
Load continues to be linked to the CR motor. /CR motor defective.
o Solution
n
Do the same correspondence as service call 00010004.
SERVICE REQ. 0001001E: PF SERVO PARAMETER ERROR
o
Problem
Load continues to be linked to the PF motor. / PF motor defective
o Solution
n
Do the same correspondence as service call 00010000.