EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
30
4.2.1.9 Roll Paper Cover Removal
1. Open the roll cover
2. Remove the upper and lower roll paper with roll shaft.
3. Remove two screws on the left roll holder and remove the left roll holder.
Figure 4-32.
4. Remove two screws on the right roll holder and remove the right roll holder.
Figure 4-33.
5. Slide the Roll paper cover, then remove it.
4.2.1.10 Front Cover Removal
1. Remove the R Side Cover.(Refer to R Side Cover Removal 124.)
2. Remove the L Side Cover.(Refer to L Side Cover Removal 124.)
3. Remove the I/C Holder Cover. (Refer to I/C Holder Cover Removal 125.)
4. Open the Front Cover.
5. Remove two hexagon screws on both side.
Figure 4-34.
6. Remove two screws fixing the Hinge unit L.
Figure 4-35.
Guide pin
Screw
Guide pin
Screw
Hexagon screw
ScrewHinge unit L