EasyManua.ls Logo

Epson StylusPro 10000 - PF Motor

Epson StylusPro 10000
323 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
67
5.3.8.2 PF Motor
Perform the PF motor reliability test.
The motor is actuated designated number.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the PF motor reliability test menu sequence.
Figure 5-99.
o
The maximum value of the paper feed is [100.0mm].
o The maximum value of the reliability number designation is [99,999,999 times].
o When the [Pause] key is pushed during the reliability test, the test can be broken.
Table 5-22.
Movement distance is less
than 8.6mm
Movement distanceis more
than 8.6mm
Speed 25 CPS 52 CPS
Acceleration speed 0.1G 0.2G
Decrease speed 0.1G 0.2G
Enter
Enter
Enter
FeedAmount:0.1mm
LifeCount:-1
Count :10
End : 50
Adjustable with "Paper Feed +/-" key
at unit of 0.1mm.
Adjustable with "Paper Feed +/-" key.

Table of Contents