Adjustment Adjustment Outline
1
90
5.1.3 Adjustment Items
All parts that require adjustment when replaced are listed in the table below.
*1: If you can backup the parameters, replace the main board and upload the parameters into the
new board. A successful backup means no adjustment is required using the self-diagnostic
function.
Table 5-2. Service Parts & Required Adjustments
Service
Operation
Adjustment Items Refer to page
Printhead
replacement
<Start-up the Self-diagnostics>
1. Head rank input (and initial ink charge)
2. Nozzle check
3. Head slant adjustment
4. Bi-D adjustment
5. Head LR adjustment
6. Test print
7. Print head life counter clear
Refer to the
Paragraph 5.3
C362 DRV Board
replacement
1. <Parameter backup> *1
2. <Reload firmware>
<Start-up the Self-diagnostics>
3. Ensure the capping position
4. Write D/A Value
5. Inputheadrank(Notnecessaryinkcharge
initialize)
6. Bi-d adjustment
7. Feed adjsutment
8. Paper feed adjsutment
9. Top & Bottom adjustment
10.Rear sensor position adjustment
11.Paper sensor adjustment
12. Test print
13.<Replace waste ink pads then clear the ink
counter.)
14.Write USB-ID
Refer to the
Paragraph
5.2.1,5.2.2,5.3
C362MAIN Board
replacement
<Reload firmware>
Firmware
Upload on
page 193
Sensor assembly
replacement
P Front
PEdge
<Start-up the Self-diagnostics>
1. Paper-Related Sensor adjustment
2. Top/bottom adjustment
Refer to the
Paragraph 5.3
CR Motor
replacement
1. <CR timing belt tension
adjustment>:Tension Gauge is required.
<Start-up the Self-diagnostics>
2. Bi-d adjustment
3. Top & Bottom adjustment
4. Test print
Refer to the
Paragraph
5.2.3.1
PF Motor
replacement
1. <PF timing belt tension
adjustment>:Tension Gauge is required.
<Start-up the Self-diagnostics>
2. Feed adjsutment
3. Top & Bottom adjustment
4. Rear sensor position adjustment
5. Test print
Refer to the
Paragraph
5.2.3.2
Sensor assembly
replacement
P_REAR/P_Front/
P_EDGE
<Start-up the Self-diagnostics>
1. Sensor adjustment
Refer to the
Paragraph 5.3
Sensor assembly
replacement
PThick
<Start-up the Self-diagnostics>
From the "Test" menu select "Sensor" and then
"Paper Thickness"
Required tool: Filler Gauge
Refer to the
Paragraph 5.3
Sensor assembly
replacement
Cover Sensor
<Start-up the Self-diagnostics>
From the "Test" menu select "Sensor" and then
"Cover"
Refer to the
Paragraph 5.3