EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
64
6. Remove the four screws (CP(W) M4x10) securing the CR motor and remove the CR
motor with roller.
Figure 4-115. CR Motor Removal
4.2.3.9 Removing the PF Motor ASSY
1. Remove the L Side Cover as described in L Side Cover Removal 124.
2. Remove the Rear Cover as described in Rear Cover Removal 126.
3. Disconnect the PF Motor ASSY cable connector.
Figure 4-116.
4. Loosen the four (CP(W) M4x10) screws securing the PF motor bracket.
A D J U S T M E N T
R E Q U I R E D
When removing the CR Motor, the following adjustment procedures
are required.
n CR Timing Belt Tension Adjustment
C A U T I O N
Pay attention so as not to scar the steel belt.
Screw
Roller
CR motor
PF Motor cable connector