EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
75
7. Remove a right side edge screw (M3x6), then remove the T fence (Scale 180a).
Figure 4-145.
4.2.3.17 Removing the Paper Hold Solenoid
1. Remove the R Side Cover as described in R Side Cover Removal 124.
2. Remove the L Side Cover as described in L Side Cover Removal 124.
3. Remove the H Top cover as described in H Top Cover Removal 123.
4. Remove the Cleaning unit, the Flashing box, the Dot missing detedtor. (Refer to
Removing the Cleaning Unit 167 /Removing Flushing Box 170 / Removing Dot
Missing Detector 171)
5. Disconnect the cable for the Paper Hold Solenoid cable from the cable connector.
Figure 4-146.
C A U T I O N
When assemble, Adjust the positions of 7 T fence hold, so that the T
fence (scale 180a) becomes a straight line.
Screw
Tfence
Solenoid
Cable connector

Table of Contents