EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
74
4. Remove five screws ( :M4x8) securing Ink Pump ASSY.
Figure 4-141.
5. Disconnect the six tubes from the air distributor.
Figure 4-142. Air tube location
4.2.3.16 Removing the T Fence (Scale 180a)
1. Remove the R Side Cover as described in R Side Cover Removal 124.
2. Remove the L Side Cover as described in L Side Cover Removal 124.
3. Remove the H Top cover as described in H Top Cover Removal 123.
4. Marking 7 place of the T fence hold position.
5. Loosen two revolution 7 place of the T fence hold, then lift up it and fixed.
Figure 4-143.
6. Remove the left side of tention spring.
Figure 4-144.
Screw
Screw
Air distributor
12
3
65
4
123
456
Black
Cyan
Magenta
Yellow
Light Magenta
Light Cyan
Tfencehold
Screw
Spring
Tfence