EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
85
4.2.3.26 Removing the P_THICK Sensor
1. Remove the H Top Cover as described in H Top Cover Removal 123.
2. Push the paper hold lever to the front. (Unlock condition)
Figure 4-172.
3. Marking the P_THICK sensor bracket position on the CR guide rail.
Figure 4-173.
4. Remove two screws (M3x6) fixing the P_THICK sensor.
Figure 4-174.
5. Disconnect the cable connector from the P_THICK Sensor.
Figure 4-175.
Paper hold lever
P_THICK sensor
Marking
CR guide rail
P_THICK sensor
Screw
Cable connector

Table of Contents

Related product manuals