EasyManua.ls Logo

Ericsson ECN320 - Port

Ericsson ECN320
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
1553-CNH 160 0787 Uen PA2 2005-09-23
123
esn <node> – The node number of the ESN310 in the format a.b
for example 0.1, which refers to the first ESN310 connected to port
25, 26 or 27 of the ECN (port 27 is only valid for ECN330).
create-trunk – Create a trunk for link aggregation
remove-trunk – Remove a trunk from the link aggregation con-
figuration
primary <port> - ESN310 port number. The port number must
always be smaller than the secondary port number. The primary
port number is in the range 1 – 23. The primary port is the one that
appears in the Inventory.
secondary <port> - ESN310 secondary port number, which
must be larger than the primary port number. Range is 2 – 24.
Default Setting
Disabled.
Command Usage
The command is used to configure a link aggregation trunk for the ESN310
switch or the ECN switch. It is available for downlink ports only.
Example
ecn330(config)# esn 0.1 link-aggregation create-trunk
primary 8 secondary 12
ecn330(config)# esn 0.1 link-aggregation remove-trunk
primary 8
11.6.5.2 port
11.6.5.2.1 phy-mode
Use this command to configure the physical mode of the ESN108 port.
Command level: ecn330(config)#.
Syntax
esn <node> port <port> phy-mode <phy-mode>
Arguments:

Table of Contents

Related product manuals