EasyManua.ls Logo

Ericsson ECN320 - Using the Console Connector

Ericsson ECN320
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
1553-CNH 160 0787 Uen PA2 2005-09-23
59
11.1 Using the Console Connector
The ECN provides an RS-232 serial port that enables a direct connection to
the ECN using for example the LCT.
To connect a terminal to the console port, complete the following steps:
1. Connect the console cable to the serial port of the ECN Local Craft
Tool, and tighten the captive retaining screws on the DB-9 connector.
2. Connect the other end of the cable to the RS-232 serial port on the
ECN.
3. Set the terminal emulation software (for example Hyper Terminal) as
follows:
Select the appropriate serial port (COM port 1 or COM port 2).
Set the data rate to 9600 baud.
Set the data format to 8 data bits, 1 stop bit, and no parity.
Set flow control to none, emulation mode to VT100.
When using HyperTerminal, select Terminal keys, not Windows
keys.
Note: When using HyperTerminal with Microsoft Windows 2000, make
sure that Windows 2000 Service Pack 2 or later is installed. Win-
dows 2000 Service Pack 2 fixes the problem of arrow keys not
functioning in HyperTerminal’s VT100 emulation
Once the terminal is set up correctly, the login session can begin.

Table of Contents