EasyManua.ls Logo

Ericsson ECN320 - Performance-Data

Ericsson ECN320
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
1553-CNH 160 0787 Uen PA2 2005-09-23
79
line
Configure the ADSL transmission proper-
ties
83
performance-data
Performance data configuration 86
pvc
Configure general setting for the pvc 87
show
Show configuration
transmission-
mode
Set different ADSL standards for the con-
nection
97
Note: Please refer to EDN288 Installation Guide for information about
what parameters has to be configured as a minimum on a port.
11.6.2.1 alarm-thresholds
Use this command to set the alarm threshold in downstream direction and
upstream direction for line performance.
Command level: ecn330(config)#.
Syntax
dslport <dslport> alarm-thresholds {down-
stream|upstream} {es-15-minutes|ses-15-minutes| uas-15-
minutes|es-24-hours|ses-24-hours|uas-24-hours} <inter-
val>
Arguments:
<dslport> - The DSL-port to configure. The parameter <a.b.c>
refers to the ECN port (a), the ESN108 port (b) and the IP DSLAM
line (c).
downstream/upstream – The thresholds can be set for both up-
stream and downstream
es-15-minutes – Sets the amount of Error Seconds (ES) in an
interval of 15 minutes that is accepted before an alarm is sent. ES
is a second with one or more errors.
ses-15-minutes – Sets the amount of Severely Error Seconds
(SES) in an interval of 15 minutes that is accepted before an alarm
is sent. SES is a second with 18 or more errors.
uas-15-minutes - Unavailable Seconds (UAS) is a second in
which the line is defined as unavailable. The line is defined as un-
available after 10 contiguous SES. The unavailable time includes

Table of Contents

Related product manuals